LXSC 13D3 ~ Class C

LXSC 13D3 ~ Class C – Dry Type Water Meter (Export Only).

APPLICATION:

Measures the volume of cold or hot potable water passing through a pipeline.

FEATURES:

• Single jet, dry Type.
• Magnetic drive.
• Optimum accuracy and performance at all times.
• Free rotating register.
• Strainer & non-return valve (NRV).
• Eight Roller display

MAXIMUM PERMISSIBLE ERRORS:

• In the lower zone from Qmin inclusive up to but excluding Qt is: Cold potable and Hot water meter ±5%
• In the upper zone from Qt inclusive up to and including Qs is: Cold potable water meter ±2%

WORKING CONDITIONS:

• Water temperature: ≤40°C for cold water.
• Water temperature: ≤90°C for hot water.
• Water pressure: ≤1.6MPa (16 Bar).

NOTE:

NOTE:
• 15mm & 20mm Brass Adaptors available for 170mm / 190mm End to End measurement respectively.

PRESSURE LOSS DATA

MAIN TECHNICAL SPECIFICATIONS

 

DIMENSIONS TABLE

 

DIMENSIONS

 

FLOW ERROR CURVE


# #

Real Time Analytics