Inferential Water Meters

LXSG 15E ~ 50E – Dry or Wet Dial Cold & Hot Water Meter (export only)

 

APPLICATION:

Measures the volume of cold or hot potable water consumed in domestic units.

FEATURES:

• Dry or wet dial.
• Direct drive.
• Brass or plastic body.
• Pointer roller indicator for easy clear reading.
• Non-return valve, inlet strainer and pulse output available on request.

MAXIMUM PERMISSIBLE ERRORS:

• In the lower zone from (qmin) inclusive up to but excluding (qt) is ±5%.
• In the upper zone from (qt) inclusive up to and including (qs) is ±2% (Hot water meter: ±3%).

WORKING CONDITIONS:

• Water temperature: ≤50°C for cold water.
• Water temperature: ≤90°C for hot water.
• Water pressure: ≤1MPa or 1.6MPa optional (10 Bar or 16 Bar optional).

COMPLIANCE STANDARD:

• ISO 4064 (GB/T778-1996).
NOTE: The flange dimension conforms to ISO7005-2:1988 Standard.

PRESSURE LOSS DATA

MAIN TECHNICAL SPECIFICATIONS

 

DIMENSIONS TABLE

DIMENSIONS

FLOW ERROR CURVE


# #