HBRP DN15 ~ DN20 Water Meter
APPLICATION:
Measures the volume of cold potable water passing through a pipeline.
FEATURES:
• Accurate registration throughout a wide flow range.
• Mechanical drive for maximum reliability.
• Corrosion resistant body.
• Clear, easily read, liquid sealed 8 digit counter.
• Registering begins at low flow rates.
• Internal non return valve and strainer.
• Optional plastic body with UV stabilizer.
• Reed switch equipped option.
• Inlet and Outlet threads compatible with I.S.O metric sizes.
• High frequency pulse output available.
• Lead seal installed after verification tests.
• Unique Serial number for each unit
MAXIMUM PERMISSIBLE ERRORS:
• In the lower zone from Qmin inclusive up to but excluding Qt is ±5%.
• In the upper zone from Qt inclusive up to and including Qmax is ±2%.
WORKING CONDITIONS:
• Water temperature: 2°C ~ 40°C.
• Water pressure: ≤1.6MPa (16bar).
COMPLIANCE STANDARD:
• Technical data conforms to ISO 4064 Class C Standard
• Hibred HBRP Brass Water Meter are tested in accordance to SABS 1529-1. All testing are done in Approved SABS TEST Facilities LAB. Performance Results are approved by SABS Trade Metrology Division, to SABS 1529/1 : 2003. ISO 4063/1.
INSTALLATION REQUIREMENTS:
• May be installed on a horizontal, vertical or inclined pipeline (vertical recommended).
• Pipeline must be flushed before installation.
• Meter should be constantly full of water during operation.