INTRODUCTION:
ADL 2006 is an electronic instrument used for detecting a leaking pipe conducting water, heating fluid or petroleum.
It is capable of detecting leaks under solid surfaces such as roads, soil etc.
It allows the user the flexibility and portability to carry out leak detection work by following set out stages.
The Instrument provides signal intensity, visible and audio indicators that enable the operator to locate the leak source promptly and accurately.
The unique noise / mute button is conveniently located on the carry handle.
The unit is light, making it easy to carry. easily replaceable Alkaline batteries are used to
supply power.
This instrument is applied in industries such as:
• Water utilities
• Heat supply companies
• Railways
• Ports
• Industrial and mining companies
enabling it to be of tremendous economic benefit.
FEATURES:
• Detect the low water leakage noise that could not be detected by the mechanical listening rod
• Easy to operate and widely application.
• LCD display with back light indicates signal intensity in two modes: normal and histogram.
• Final leakage noise can be stored, which is useful when makeing comparison of water leakage noises at different locations.
• Small size and light weight.
• Water leak detection Handle type probe with user-friendly design allows for detection over a large area.
• Ergonomically designed handle with ground microphone
• Handle mute button is easy to use and able to control the signal noise to prevent hearing harm.
• Filtering settings to enhance the leakage signals and eliminate interfering signals.
• Alkaline battery power supply.
• High-fidelity ambient noise prevention headphone.
TECHNICAL DATA:
Display: 128 × 64 dot matrix LCD with backlight
Sensor Type: Piezoelectric ceramics acceleration Sensor
Sensitivity: >800mV/g
Frequency Range: 240Hz
400Hz
240Hz – 650Hz
240Hz – 1100Hz
240Hz – 1800Hz
650Hz – 3000Hz
Amplification: 120dB
Histogram: 5 columns;
Battery: 8 × 1.5v AA alkaline batteries
Operating Time: >48h
Automatic Shutdown: Automatic shutdown if there is no activity within half an hour
Mute Button: Handle / Keypad
Maximum Output: 600mW
Operating Temperature: -20°C ~ +50°C
Storage Temperature: -20°C ~ +70°C
Size (L × W × D): 150 × 100 × 100mm
Weight: 1KG
Environmental: IP54
CONTENTS:
ADL2006 Detector
Ground Microphone
Headphone
8 x 1.5v AA alkaline batteries
Transport Case
Instruction Manual